Direct & Inverted Pendulum Reading Table

Direct pendulum

The direct pendulum consists of a wire suspended from the upper point and a reading station fixed to the structure at the lower point. The wire is tensioned by a suspended weight submerged in a damper tank.

Inverted pendulum

The fixed end of the inverted pendulum is grouted at the lower point of the system. A float tensions the wire vertically. When anchored to a fixed point in the foundation, it measures absolute displacement of points along the wire.

The monitoring of the wire position for both direct and inverted pendulums can be done manually and/or electrically with a remote readout unit (ref: Model RxTx Telependulum – see separate brochure). The method of reading depends upon the concept of monitoring, the expected values of movements, and the accuracy required.

Manual Reading Options and Interpretations

A) Sighting reading table Model 76

To take a reading, the operator aligns the cursors with their respective sights and with the pendulum wire. The positions of the cursors are read directly off the scale and the vernier cursor. The readings are converted to wire displacement values using the chart provided with each reading station.

B) Optical coordinoscope Model MVR

The setup consists of a reference base permanently installed at the reading point. The coordinoscope is then installed on its reference section respectively at X and Y axes on the base frame. Measurements are taken by focusing or aiming the lens at the pendulum wire and by reading the current lateral displacement on the vernier.

Available Products

Direct & Inverted Pendulum Reading Table
[Direct & Inverted Pendulum Reading Table]
Please contact for pricing

-

Product Details

SPECIFICATIONS

PENDULUM COMPONENTS

   Direct pendulum

Stainless steel or invar wire

Upper hook and vee-shaped guide bracket

Wire tensioning weight and hook

Damper tank

   Inverted pendulum

Wire (same as for direct pendulum)

Anchoring weight

PVC float and float tank assembly

MODEL 76 

   Range

±15 mm

   Resolution

0.1 mm

   Accuracy

0.5 mm

   Reading station component

Stainless steel table

(includes scales, cursors, sights and chart for evaluating wire position)

MODEL MVR 

   Range

400 mm

   Accuracy

0.02 mm

   Focal range

±50 mm

   Overall dimensions

500 x 500 mm

 

    Please specify:

  • Type of pendulum
  • Wire length
  • Manual or remote reading station

    Optional accessories:

  • Mounting brackets
  • Creep test kit for long term testing at constant pressure

+

Documentation

Name
Description
Action
Document Name: Direct & Inverted Pendulum Reading Table 
Document Type: Spec Sheet